Dr. REENA SETHI
Dr. ADITYA SETHI, Dr.ARUN SETHI, Dr. SAHEBAAN SABHARWAL
Abstract
Purpose
Capsulorrhexis in Intumescent cataracts have been much talked about, with newer technologies like zepto, FLACS coming in. We present a more simpler, less glorified way of HOLDING THE DOOR of the capsule for a precise, safe and complete CCC.
Methods
Retrospective analysis of intumescent cataracts were documented, video studied of this pinch, grasp and hold technique of CCC with great repeatability, success and results. This was later repeated by 8 more surgeons of varied experience with equal ease, success reconfirming its validity, safety and repeatability.
Results
Close to 300 eyes with Intumescent cataract over the last 3 years were documented with this technique with a staggering complication rate of less than 2% , which were rhexis run out, incomplete rhexis or tear. This was repeatable in all cases and even in special situations like loose zonules.
Conclusion
This is a safe, repeatable, cheap method which is often less glorified than its expensive competitors.
Full Text